Belden 88770 Cable Equivalent, FEP-TFE, Price $490/1000 ft.
Detailed Specifications and Technical Data

Description: 18 AWG stranded (19x30) TC conductors, FEP insulation, three conductor, overall foil shield (100% coverage), 20 AWG stranded TC drain wire, FEP jacket - Red. Plenum Rated CMP.

Physical Characteristics:
BELDEN 88770 CABLE
CONDUCTOR:
PRICE $490/1000 ft.

Number of Pairs 1
Total Number of Conductors 3
AWG 18
Stranding 19x30
Conductor Material TC - Tinned Copper
BELDEN 88770 CABLE INSULATION:
Insulation Material FEP - Fluorinated Ethylene Propylene
Nom. Insulation Wall Thickness .007 in.
Lay Length 1.75 in.
Twists/ft. 6.9
Pair Color Code Chart:
Number: 1

Black, White, Red
BELDEN 88770 OVERALL CABLING:
Overall Cabling Separator Material Polyester tape
Overall Cabling Separator Thickness 0.001 in.
BELDEN 88770 CABLE OUTER SHIELD:
Outer Shield Type Tape
Outer Shield Material Aluminum Foil-Polyester Tape
Outer Shield % Coverage 100%
BELDEN 88770 CABLE OUTER SHIELD DRAIN WIRE:
Outer Shield Drain Wire AWG 20
Outer Shield Drain Wire Stranding Stranded
Outer Shield Drain Wire Conductor Material TC - Tinned Copper
BELDEN 88770 CABLE OUTER JACKET:
Outer Jacket Material FEP - Fluorinated Ethylene Propylene
Outer Jacket Nominal Wall Thickness .014 in.
BELDEN 88770 CABLE OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .155 in.
BELDEN 88770 CABLE MECHANICAL CHARACTERISTICS:
Operating Temperature Range -70°C To +200°C
Bulk Cable Weight 31 lbs/1000 ft.
Max. Recommended Pulling Tension 74 lbs.
Min. Bend Radius (Install) 1.6 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
BELDEN 88770 CABLE APPLICABLE STANDARDS:
NEC/(UL) Specification CMP
CEC/C(UL) Specification CMP
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
BELDEN 88770 CABLE FLAME TEST:
UL Flame Test NFPA 262
C(UL) Flame Test FT6
BELDEN 88770 CABLE SUITABILITY:
Suitability - Indoor Yes
Suitability - Outdoor Yes
Suitability - Burial Yes
Oil Resistance Yes
BELDEN 88770 CABLE ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance  --
Nom. Inductance .15 £gH/ft
Nom. Capacitance Cond. to Cond. @ 1 KHz 56 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 96 pF/ft
Nominal Velocity of Propagation --
Nominal Delay  --
Nom. Conductor DC Resistance @ 20°C 6.4 Ohms/1000 ft
Nom. Outer Shield DC Resistance @ 20°C 7.3 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS
Max. Recommended Current 8 Amps per conductor @ 25°C
NOTES: For use in indoor plenum environments but also suitable for outdoor and underground applications.

PUT-UPS AND COLORS - ALL SPOOLS ARE CONTINUOUS LENGTHS
88770 Cable
$490/1000 ft.
Put-Up (ft.) Ship Weight Jacket Color
88770 Cable 1000 28 lbs. RED
88770 Cable 2000 56 lbs. RED
88770 Cable 2500 70 lbs. RED
88770 Cable 3000 84 lbs. RED
88770 Cable 5000 140 lbs. RED

PlenumCable2.com is a division of WorldWideWire.com.